The Device is produced in accordance with TU BY 100185185.251-2017 Standard.
Application
The Device is intended for installation in the air system of heavy vehicles, buses, trolleybuses and agricultural vehicles for maintaining 0.65 … 0.8 MPa air pressure pumping by the vehicle compressor.
Specifications
Parameter name |
Parameter value |
Max operating pressure, MPa |
1.35 |
Actuation pressure, MPa |
0.65+0.05 |
Deactuation pressure, MPa |
0.8-0.05 |
Relief valve actuating pressure, MPa |
1 … 1.35 |
Bypass valve actuating pressure, MPa |
0.2 … 0.25 |
Fitting thread, mm for regulator for heating unit for cartridge |
М 22´1.5; М 12´1.5; М 27´1 М 39´1.5 |
Heater rated voltage, W |
125 |
Rated voltage, V |
24 |
Heater cut-in temperature, °С |
7 |
Heater cutoff temperature, °С |
35 |
Operating temperature range, °С |
- 50 … +100 inclusive* |
Overall dimensions, mm, max |
198´158´132 |
Weight, kg, max |
1.72 |
Heating unit cover colour |
black |
*Operating temperature can shortly increase up to +120°С with specifications modification. |