SGD-3T Diaphragm gas meter with temperature compensator

The gas meter is equipped with a temperature compensator SGD-3T which performs correction of registration of the gas meter depending on the temperature of the gas within a range from – 40oC to +35 oС°.
The additional relative error of a gas meter caused by a deviation of a temperature of a gas being measured from normal temperature (20±3)oC should not exceed ±0,1 % in comparison with the basic relative error at temperature change by 1oC, and for a temperature above +35 oC - 0,45 %.
The gas meter is designated for operation at a temperature from – 40 oC to +50oC.
The pulse output device is embedded in gas meters of versions SGD-3T, SGD-3T-2I which allows to embed gas meters in the system of automated collection and processing of information.
|
Technical Data:
|
|||||
|
Standard Size
|
G4
|
G6
|
|||
|
|
SGD-3T-1-1
|
SGD-3T-2-1
|
SGD-3T-1-1
|
SGD-3T-2-1
|
|
|
|
SGD-3T-1-2
|
SGD-3T-2-2
|
SGD-3T-1-2
|
SGD-3T-2-2
|
|
|
Gas rated consumption Qrated, m³/h
|
4
|
6
|
|||
|
Gas maximum consumption Qmax, m³/h
|
6
|
10
|
|||
|
Gas minimum consumption Qmin, m³/h
|
0,04
|
0,06
|
|||
|
Maximum operating pressure, kPa
|
60
|
||||
|
Measurement error:
|
|
|
|
|
|
|
- at consumption from Qmin to 0,1 Qrated, % , max.
|
±3
|
||||
|
- at consumption from 0,1 Qrated to Q max., % , max.
|
±1,5
|
||||
|
Threshold response, m³/h, max
|
0,002Qrated
|
||||
|
Operating temperature, °С
|
-40 - +50
|
||||
|
Distance between nipple axes, mm
|
-40 - +35
|
||||
|
Thread on connection of gas meter GOST 6357-81
|
200±0,5
|
250±0,5
|
200±0,5
|
250±0,5
|
|
|
|
G1 1/4
|
||||
|
Overall dimensions, mm
|
265х185х250
|
310х185х245
|
265х185х250
|
310х185х245
|
|
|
Weight, max., kg
|
3,8
|
4,3
|
3,8
|
4,3
|
|
|
Calibration interval, years
|
8
|
||||
|
Gas meter life time, years
|
20
|
||||
|
Warranty life, months
|
24
|
||||
-
Order product
-
Feedback